You are viewing the site in preview mode

Skip to main content

Table 2 Summary of treatment parameters in the three centers

From: Factors affecting outcome in frameless non-isocentric stereotactic radiosurgery for trigeminal neuralgia: a multicentric cohort study

 nMean (SD)MedianMinMax
Volume (mm3)Center A17629.0 (14.3)25.05.0103.3
Center B8027.7 (12.3)30.010.070.0
Center C4023.8 (12.8)20.010.060.5
Overall29628.0 (13.7)25.05.0103.3
Prescription dose (Gy)Center A17657.7 (6.7)60.035.090.0
Center B8057.4 (2.6)58.038.060.0
Center C4060.2 (4.1)60.049.070.0
Overall29658.0 (5.6)60.035.090.0
Isodose (%)Center A17683.0 (3.2)83.073.090.0
Center B8080.0 (0.4)80.078.080.0
Center C4080.0 (3.2)80.070.085.0
Overall29681.6 (3.1)80.070.090.0
Dmax (Gy)Center A17670.0 (8.1)71.342.7112.5
Center B8072.0 (3.3)72.547.575.0
Center C4075.7 (4.0)75.070.087.5
Overall29671.1 (7.0)72.442.7112.5
Dmean (Gy)Center A17663.7 (7.3)65.338.8101.3
Center B8064.7 (2.9)65.342.867.5
Center C4068.1 (3.8)67.559.880.1
Overall29664.5 (6.2)65.338.8101.3
Integral dose (mJ)Center A1762.0 (0.9)1.60.36.7
Center B801.8 (0.8)1.90.64.4
Center C401.6 (0.8)1.40.74.0
Overall2961.8 (0.9)1.60.36.7